Control
-
Lutze 728754 dra60-24
Lutze
$82.11Technical Data Input Number of phases 1 Rated voltage UN AC 100??240 V Operation voltage range AC 85??264 V / DC 90??375 V Line frequency 47??63 Hz Rated current IN 690 mA @ AC 115 V / 360 mA @ AC 230 V Inrush current ...728754$82.11 -
Lutze 723700 cpsb1-480-24r
Lutze
$507.62Technical Data Input Number of phases 1 Rated voltage UN AC 120/240 V Operation voltage range AC 90???264 V / DC 110???345 V Line frequency 47???63 Hz Rated current IN 4.8 A @ AC 120 V / 2.4 A @ AC 240 V Inrush...723700$507.62 -
Lutze 723600 cpsb1-240-24r
Lutze
$182.03Technical Data Input Number of phases 1 Rated voltage UN AC 120/240 V (manual) Operation voltage range AC 90???132 V / AC 187???264 V, DC 270???345 V Line frequency 47???63 Hz Rated current IN 4 A @ AC 120 V / 2 A @ AC...723600$182.03 -
Lutze 723500 cpsb1-120-24e
Lutze
$110.18Technical Data Input Number of phases 1 Rated voltage UN AC 120/240 V Operation voltage range AC 85??264 V / DC 110??345 V Line frequency 47??63 Hz Rated current IN 2.1 A @ AC 120 V / 1.2 A @ AC 240 V Inrush current ...723500$110.18 -
Lutze 723120 cbu150u
Lutze
$708.89Technical Data Input Input voltage DC 12 V / 24 V / 48 V / 72 V or automatic recognition Input current max. DC 20 A Status display input LED green: selected voltage Parameterisation ButtonSelection of input voltage Energy...723120$708.89 -
Lutze 723115 cnbp30
Lutze
$161.74Technical Data Energy storage Memory type 2????? lead batteries DC 12 V / 1.2 Ah max. charging current 600 mA @ DC 12 V, 300 mA @ DC 24 V Fuse for memory medium 15 A, automatic resetting Output Max. output current 5 A @ DC 2 V,...723115$161.74 -
Lutze 723110 cnups24
Lutze
$218.50Technical Data Input Input voltage DC 26 ?? 28.5 V Input current DC 3 ?? 20 mA Status display input LED green: PS Ok, LED red: Reverse polarityLED green: Battery OK, LED red: Battery low Parameterisation Button/LCD...723110$218.50 -
Lutze 723100 cdcu20 12/24dc ups
Lutze
$899.51Technical Data Input Input voltage DC 12 V or 24 V Input current max. DC 20 A Status display input see monitoring Parameterisation Button/LCD displaySoftware Powermaster(free Download L??ªtze web page) Protection device Input...723100$899.51 -
Lutze 722999 cpsrm50
Lutze
$500.67Technical Data Input No. of inputs 2 Operation voltage range DC 12????85 V No. of inputs 2 Rated current IN max. 50 A per input Output Voltage drop <0.2 V Max. output current 300 A Heat dissipation max. 10...722999$500.67 -
Lutze 722996 cpsb-123-240-24
Lutze
$275.36Technical Data Input Number of phases 3 Rated voltage UN AC 200??500 V Operation voltage range AC 187??550 V / DC 250??725 V (UL: DC 300??500 V) Line frequency 47??63 Hz Rated current IN 1-/2-phase: 2.2 A @ AC 220 V / 1.1 A...722996$275.36 -
Lutze 722995 cpsb2-120-24
Lutze
$271.14Technical Data Input Number of phases 2 Rated voltage UN AC 200??500 V Operation voltage range AC 187??550 V / DC 270??725 V Line frequency 47??63 Hz Rated current IN 1.4 A @ AC 200 V / 0.7 A @ AC 500 V Inrush current ...722995$271.14 -
Lutze 722987 drp20-24
Lutze
$58.46Technical Data Input Rated voltage UN DC 24 V No. of inputs 2 Operation voltage range DC 21??28 V No. of inputs 2 Rated current IN max. 20 A in total Output Rated voltage UN 24V Rated current IN 20 A ...722987$58.46 -
Lutze 722816 cpsb3-2400-48
Lutze
$3,120.79Technical Data Input Input protection Surge protection according to VDE 0160, over/undervoltage (auto restart)Phase monitoring (reduced output power): PFC error Number of phases 3 Rated voltage UN 3 ?? AC 400???500 V Operation...722816$3,120.79 -
Lutze 722814 cpsb3-2400-24
Lutze
$3,282.58Technical Data Input Input protection Surge protection according to VDE 0160, over/undervoltage (auto restart)Phase monitoring (reduced output power): PFC error Number of phases 3 Rated voltage UN 3 ?? AC 400???500 V Operation...722814$3,282.58 -
Lutze 722813 cpsb3-960-72
Lutze
$1,141.95Technical Data Input Number of phases 3 Rated voltage UN 3 ?? AC 400??500 V Operation voltage range 3 ?? AC 340??550 V Line frequency 47??63 Hz Rated current IN 2.4 A @ AC 400 V / 2.1 A @ AC 500 V Inrush current ...722813$1,141.95 -
Lutze 722812 cpsb3-960-48
Lutze
$1,105.05Technical Data Input Number of phases 3 Rated voltage UN 3 ?? AC 400??500 V Operation voltage range 3 ?? AC 340??550 V Line frequency 47??63 Hz Rated current IN 2.4 A @ AC 400 V / 2.1 A @ AC 500 V Inrush current ...722812$1,105.05 -
Lutze 722811 cpsb3-960-24
Lutze
$625.65Technical Data Input Number of phases 3 Rated voltage UN 3 ?? AC 400??500 V Operation voltage range 3 ?? AC 340??550 V Line frequency 47??63 Hz Rated current IN 2.4 A @ AC 400 V / 2.1 A @ AC 500 V Inrush current ...722811$625.65 -
Lutze 722805 wra480-24
Lutze
$291.82Technical Data Input Number of phases 3 Rated voltage UN 3 ????? AC 380????480 V Operation voltage range 3 ????? AC 340????575 V / 3 ????? DC 480????820 V Line frequency 47????63 Hz Rated current IN 1.5 A @ AC 400 V / 1.2 A...722805$291.82 -
Lutze 722804 wra240-24
Lutze
$188.78Technical Data Input Number of phases 3 Rated voltage UN 3 ????? AC 340??500 V Operation voltage range 3 ????? AC 340??575 V / 3 ????? DC 480??820 V Line frequency 47??63 Hz Rated current IN 0.85 A @ AC 380 V / 0.7 A @ AC...722804$188.78 -
Lutze 722803 wra120-24
Lutze
$143.52Technical Data Input Number of phases 3 Rated voltage UN 3 ????? AC 380????480 V Operation voltage range 3 ????? AC 340????575 V / 3 ????? DC 480????820 V Line frequency 47????63 Hz Rated current IN 0.5 A @ AC 380 V / 0.35...722803$143.52