Description
Technical Data
- Communication: PROFIBUS
- Topology: Subring, single-fiber ring
- Number of fieldbus nodes on the master max.: 10
- Baud rate: 93.75 kBd 1.5 MBd
- Fieldbus segment length max.: 25 m
- Transmission medium: APF (plastic) fiber (1000m)
- Number of modules per node max.: 64
- Input and output process image (Fieldbus) max.: 128 Byte/128 Byte
- System supply voltage: DC 24 V(-15 +20 %); via wiring level (CAGE CLAMP<sup></sup> connection)
- Current consumption, system supply (5 V): 350 mA
- Total current for system supply: 1650 mA
- Field supply voltage: DC 24 V (-15 +20 %); via power jumper contacts
- Input current typ. at rated load (24 V): 500 mA
- Efficiency of the power supply (typ.) at nominal load (24 V): 87 %
- Isolation: 500 V system/supply
- Number of outgoing power jumper contacts: 3
- Current carrying capacity of the power jumper contacts: 10 A
- Standard: EN 50170
Connection Data
- Connection technology: communication/fieldbus: PROFIBUS: 1 x HP Simplex, FOC plug included with delivery
- Connection technology: field supply: 6 x CAGE CLAMP<sup></sup>
- Connection technology: system supply: 2 x CAGE CLAMP<sup></sup>
- Connection technology: Device configuration: 1 x 4-pole male connector
- Connection type (1): System/field supply
- Solid conductor: 0.08 2.5 mm / 28 14 AWG
- Fine-stranded conductor: 0.08 2.5 mm / 28 14 AWG
- Strip length: 8 9 mm / 0.31 0.35 inch
Geometrical Data
- Width: 50.5 mm / 1.988 inch
- Height: 71.1 mm / 2.799 inch
- Height from upper-edge of DIN-35 rail: 63.9 mm / 2.516 inch
- Depth: 100 mm / 3.937 inch
Mechanical Data
- Type of mounting: DIN-35 rail
Material Data
- Color: light gray
- Housing material: Polycarbonate, polyamide 6.6
- Fire load: 0.000 MJ
- Weight: 191.000 g
- Conformity marking: CE
Environmental Requirements
- Surrounding air (operating) temperature: 0 55 C
- Surrounding air (storage) temperature: -40 85 C
- Protection class: IP20
- Degree of pollution (5): 2 per IEC 61131-2
- Operating altitude: 0 2000 m
- Mounting position: horizontal (standing/lying) or vertical
- Relative air humidity (no condensation): 95 %
- Vibration resistance: acc. to IEC 60068-2-6
- Shock resistance: 15g per IEC 60068-2-27
- EMC immunity to interference: acc. to EN 61000-6-2
- EMC emission of interference: acc. to EN 61000-6-4
- Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
- Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %: 10 ppm
- Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %: 25 ppm
Commercial data
- Packaging type: BOX
- Country of origin: DE
- GTIN: 4050821286042
- Customs Tariff No.: 85176200000
The WAGO 750 series Fieldbus coupler, also known as a remote I/O (RIO) controller unit, supports PROFIBUS DP communication with a data rate of 1.5MBd and can handle up to 64 connections per node and 10 fieldbus nodes on a master connection. It operates on a 24Vdc supply voltage via system wiring and power jumper, featuring a 4-pin male connector for fieldbus, spring CAGE CLAMP for power supply connections, and another 4-pin male connector for device configuration. Designed for DIN-35 rail mounting with a width of 50.5mm, it is rated for an ambient temperature range of 0°C to +55°C and has an IP20 protection rating, equivalent to model 750331.