Permissible Ambient Air Temperature Around The Device:
105 °C power amplifier || 110 °C motor
Sustainable Offer Status:
Green Premium product
Maximum Switching Current:
100 mA per output || 200 mA total
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Device Short Name:
ILS
Holding Brake:
with
Product Certifications:
UL || TÃV || cUL
China Rohs Regulation:
X
Communication Interface:
Ethernet/IP, Integrated
Rohs Exemption Information:
Yes
Accuracy Error:
+/- 6 arc min
Maximum Mechanical Speed:
3000 rpm
Brake Release Time:
40 ms
Protection Type:
short circuit of the output voltage || safe torque off || overload of output voltage
Shaft Diameter:
12 mm
Rotor Inertia:
2.4 kg.cm²
Maximum Axial Force Fa:
170 N tensile force) || 30 N force pressure)
Associated Fuse Rating:
16 A
Marking:
CE
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Mounting Support:
flange
Shock Resistance:
150 m/s² 1000 shocks IEC 60068-2-29
Commissioning Interface:
RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)
Motor Flange Size:
85 mm
Warranty:
18 months
Ambient Air Temperature For Storage:
-25-70 °C
Shaft End:
untapped
Centring Collar Diameter:
60 mm
Standards:
IEC 50347 || IEC 60072-1 || EN 61800-3 : 2001-02 || IEC 61800-3 || IEC 50178 || IEC 61800-3, Ed 2 || EN 61800-3:2001, second environment
Phase:
single phase
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
5.4 kg
Operating Altitude:
<= 3280.84 ft (1000 m) without derating
[Us] Rated Supply Voltage:
24 V || 48 V
Type Of Cooling:
natural convection
Motor Type:
3-phase stepper motor
Supply Voltage Limits:
18-55 V
Gear Box Type:
without
Brake Application Time:
20 ms
Mercury Free:
Yes
Vibration Resistance:
20 m/s² 10-500 Hz) 10 cycles IEC 60068-2-6
Speed Feedback Resolution:
20000 points/turn
Ambient Air Temperature For Operation:
40-55 °C with power derating of 2 % per °C) || 0-40 °C without derating)