40-55 °C with power derating of 2 % per °C) || 0-40 °C without derating)
Phase:
single phase
Centring Collar Depth:
2 mm
Number Of Motor Poles:
6
Shaft Diameter:
8 mm
Maximum Axial Force Fa:
30 N force pressure) || 30 N tensile force)
Environmental Disclosure:
ENVPEP2011005EN
Maximum Supply Current:
0.1 A power stage disabled) || 7 A 48 V || 9.5 A 24 V
Shaft Length:
25 mm
Voltage State 1 Guaranteed:
15...30 V
Peak Stall Torque:
0.8 N.m 24 V || 0.8 N.m 48 V
Operating Altitude:
<= 3280.84 ft (1000 m) without derating
Accuracy Error:
+/- 0.5 °
Vibration Resistance:
20 m/s² 10-500 Hz) 10 cycles IEC 60068-2-6
Circle Diameter Of The Mounting Holes:
73.54 mm
Maximum Switching Current:
100 mA per output || 200 mA total
Input/Output Type:
4 signals (each be used as input or output)
Shock Resistance:
150 m/s² 1000 shocks IEC 60068-2-29
Protection Type:
short circuit of the output voltage || safe torque off || overload of output voltage
Rotor Inertia:
0.34 kg.cm²
Number Of Motor Stacks:
2
Length:
140 mm
Nominal Torque:
0.5 N.m 24 V || 0.5 N.m 48 V
Range Of Product:
Lexium integrated drive
Voltage State 0 Guaranteed:
-3...4.5 V
Type Of Cooling:
natural convection
Maximum Mechanical Speed:
7000 rpm || 5000 rpm
Commissioning Interface:
RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-25-70 °C
Supply Voltage Limits:
18-55.2 V
Electrical Connection:
industrial connector
Associated Fuse Rating:
16 A
Pvc Free:
Yes
Transmission Rate:
10, 100 Mbits
Maximum Radial Force Fr:
80 N
Warranty:
18 months
Mounting Holes Diameter:
4.4 mm
Feedback Type:
BLDC encoder
Continuous Stall Torque:
0.54 N.m
Gear Box Type:
without
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Motor Flange Size:
66 mm
Discrete Input Current:
10-10 mA at 24 V on/STO_A safety input || 3-3 mA at 24 V on/STO_B safety input || 2-2 mA at 24 V 24 V signal interface
Nominal Output Power:
162 W 24 V || 262 W 48 V
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
cUL || UL || TÃV
Centring Collar Diameter:
40 mm
Detent Torque:
0.106 N.m
Network Type:
DC
Permissible Ambient Air Temperature Around The Device:
105 °C power amplifier || 110 °C motor
Second Shaft:
without second shaft end
Standards:
IEC 60072-1 || EN 61800-3 : 2001-02 || IEC 50347 || IEC 61800-3, Ed 2 || IEC 61800-3 || EN 61800-3:2001, second environment || IEC 50178
This product is part of the Lexium ILA, ILE, ILS range, an offer of motion integrated drives for motion control. The integrated motion drive with a 6-pole stepper motor features an integrated Modbus...