Schneider Electric ILE2K661PB1A8 Lexium Ile Bldc Mot 24 48V Eth Ip Gear
SKU:
ILE2K661PB1A8
UPC:
3606485204758
MPN:
Condition:
New
Voltage State 0 Guaranteed:
-3...4.5 V
Pvc Free:
Yes
Length:
229 mm
Feedback Type:
BLDC encoder
Peak Stall Torque:
24.72 N.m 24 V || 24.72 N.m 48 V
Communication Interface:
Ethernet/IP, Integrated
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rotor Inertia:
1980 kg.cm²
Mercury Free:
Yes
Maximum Radial Force Fr:
200 N
Motor Type:
brushless DC motor
Circularity Profile:
ENVEOLI1411012EN
Holding Brake:
without
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environmental Disclosure:
ENVPEP1411012EN
Reduction Ratio:
115:1 (3675:32)
Maximum Axial Force Fa:
80 N
Device Short Name:
ILE
Voltage State 1 Guaranteed:
15...30 V
Rohs Exemption Information:
Yes
Nominal Speed:
35 rpm 24 V || 35 rpm 48 V
Maximum Switching Current:
100 mA per output || 200 mA total
Operating Altitude:
<= 3280.84 ft (1000 m) without derating
Continuous Stall Torque:
14 N.m
Speed Feedback Resolution:
12 points/turn motor || 0.26° gearbox output
Shock Resistance:
150 m/s² 1000 shocks IEC 60068-2-29
Current Consumption:
7000 mA peak || 5500 mA maximum continuous
Ambient Air Temperature For Storage:
-25-70 °C
Protection Type:
overload of output voltage || safe torque off || short circuit of the output voltage
Discrete Output Voltage:
23...25 V
Phase:
single phase
Range Of Product:
Lexium integrated drive
Detent Torque:
16.7 N.m
Product Certifications:
UL || cUL || TÃV
Number Of Mounting Holes:
2
Number Of Motor Stacks:
1
Associated Fuse Rating:
16 A
Commissioning Interface:
RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds)
Input/Output Type:
4 signals (each be used as input or output)
Number Of Motor Poles:
6
Gear Box Type:
worm gear, 3 stages
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Operation:
40-55 °C with power derating of 2 % per °C) || 0-40 °C without derating)
Marking:
CE
Standards:
IEC 50347 || EN 61800-3:2001, second environment || IEC 60072-1 || EN 61800-3 : 2001-02 || IEC 61800-3, Ed 2 || IEC 61800-3 || IEC 50178
China Rohs Regulation:
X
Discrete Input Current:
10-10 mA at 24 V on/STO_A safety input || 3-3 mA at 24 V on/STO_B safety input || 2-2 mA at 24 V 24 V signal interface
Centring Collar Diameter:
36 mm
Network Type:
DC
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
This product is part of the Lexium ILE range, an offer of integrated motion drives for motion control. The motion integrated drive with a 6-pole brushless DC motor features an integrated EtherNet/IP...
This product is part of the Lexium ILE range, an offer of integrated motion drives for motion control. The motion integrated drive with a 6-pole brushless DC motor features an integrated EtherNet/IP...
This product is part of the Lexium ILE range, an offer of integrated motion drives for motion control. The motion integrated drive with a 6-pole brushless DC motor features an integrated EtherNet/IP...
This product is part of the Lexium ILE range, an offer of integrated motion drives for motion control. The motion integrated drive with a 6-pole brushless DC motor features an integrated EtherNet/IP...