Schneider Electric ATV950D30N4U Atv950 Ip55 Ultype12 30Kw 400V/480V Vari
SKU:
ATV950D30N4U
UPC:
3606481284327
MPN:
Condition:
New
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Quantity Per Set:
1
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Motor Power Kw:
30.0 kW normal duty || 22.0 kW heavy duty
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Ambient Air Transport Temperature:
-40-70 °C
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Product Specific Application:
process for industrial
Product Destination:
synchronous motors || asynchronous motors
Product Or Component Type:
variable speed drive
Connector Type:
2 RJ45 || 1 RJ45
Product Certifications:
DNV-GL || TÃV || ABS || ATEX INERIS || CSA || UL || Bureau Veritas
Base Load Current At Low Overload:
61.5 A
Mounting Mode:
wall mount
Base Load Current At High Overload:
46.3 A
Asynchronous Motor Control Profile:
variable torque standard || constant torque standard || optimized torque mode
Operating Position:
vertical +/- 10 degree
With Safety Function Safely Limited Speed (Sls):
TRUE
With Safety Function Safe Torque Off (Sto):
TRUE
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
With Safety Function Safe Speed Monitor (Ssm):
FALSE
With Safety Function Safe Stop 1 (Ss1):
TRUE
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Discrete Output Type:
logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Width:
290 mm
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-40-70 °C
Motor Slip Compensation:
automatic whatever the load || not available in permanent magnet motor law || can be suppressed || adjustable
Prospective Line Isc:
50 kA
Net Weight:
50 kg
Number Of Addresses:
1-247 Modbus serial
Discrete Output Number:
2
China Rohs Regulation:
X
With Safety Function Safe Position (Sp):
FALSE
Line Current:
53.3 A 380 V normal duty) || 40.5 A 380 V heavy duty) || 45.9 A 480 V normal duty) || 35.8 A 480 V heavy duty)
Apparent Power:
29.8 kVA 480 V heavy duty) || 38.2 kVA 480 V normal duty)
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Maximum Acceleration Under Shock Impact (During Operation):
150 m/s² at 11 ms
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Ip Degree Of Protection:
IP55
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Ambient Air Temperature For Operation:
-15-40 °C without derating) || 40-50 °C with derating factor)
Method Of Access:
slave Modbus TCP
Isolation:
between power and control terminals
Environmental Disclosure:
ENVPEP1506001EN
Analogue Input Number:
3
Number Of Addresses:
1-247
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Depth:
340 mm
Transmission Frame:
RTU
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Upgradeability:
Upgraded components available
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Continuous Output Current:
61.5 A 4 kHz normal duty || 46.3 A 4 kHz heavy duty
Marking:
CE
Degree Of Protection:
UL type 12
Type Of Polarization:
no impedance Modbus serial
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
4 Quadrant Operation Possible:
TRUE
Maximum Output Frequency:
599 Hz
Electrical Connection:
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 25...50 mm² AWG 4...AWG 1 || motor screw terminal 25...50 mm² AWG 4...AWG 1 || DC bus screw terminal 25...50 mm² AWG 4...AWG 1
Overvoltage Category:
III
Noise Level:
69.7 dB 86/188/EEC
Sustainable Offer Status:
Green Premium product
Analogue Output Number:
2
Network Frequency:
50-60 Hz
With Safety Function Safe Direction (Sdi):
FALSE
Discrete Input Logic:
16 preset speeds
Maximum Output Voltage:
480.0 V
Switching Frequency:
2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current:
73.8 A 60 s normal duty) || 69.5 A 60 s heavy duty)