Schneider Electric ATV930D11N4ZU Atv930 T12 Rdy Ip20 15Hp 400V Wo Keypad Pack of 7
SKU:
ATV930D11N4ZU
UPC:
3606489740252
MPN:
Condition:
New
Transmission Frame:
RTU
Upgradeability:
Upgraded components available
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Number Of Addresses:
1-247 Modbus serial
Apparent Power:
14.1 kVA 480 V normal duty) || 10.4 kVA 480 V heavy duty)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Permitted Relative Humidity (During Operation):
class 3K5 according to EN 60721-3
Operating Position:
vertical +/- 10 degree
With Safety Function Safe Torque Off (Sto):
TRUE
Ambient Air Temperature For Storage:
-40-70 °C
Noise Level:
56 dB 86/188/EEC
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Type Of Polarization:
no impedance Modbus serial
4 Quadrant Operation Possible:
TRUE
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
With Safety Function Safe Brake Management (Sbc/Sbt):
TRUE
Motor Power Kw:
11.0 kW normal duty || 7.5 kW heavy duty
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Maximum Switching Current:
relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R
Maximum Deflection Under Vibratory Load (During Operation):
1.5 mm at 2...13 Hz
Option Card:
slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module
Analogue Input Number:
3
Height:
345 mm
Maximum Output Voltage:
480.0 V
Network Frequency:
50-60 Hz
Data Format:
8 bits, configurable odd, even or no parity Modbus serial
With Safety Function Safe Direction (Sdi):
FALSE
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Device Application:
Industrial Application
With Safety Function Safe Stop 1 (Ss1):
TRUE
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Ip Degree Of Protection:
IP21
Emc Filter:
integrated || with EMC plate option
Product Certifications:
UL || TÃV || CSA
Environmental Disclosure:
ENVPEP2007010EN
With Safety Function Safe Position (Sp):
FALSE
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Data Format:
8 bits, configurable odd, even or no parity
Ambient Air Transport Temperature:
-40-70 °C
Number Of Addresses:
1-247
Pollution Degree:
2
Prospective Line Isc:
50 kA
Marking:
CE
Continuous Output Current:
23.5 A 4 kHz normal duty || 16.5 A 4 kHz heavy duty
Asynchronous Motor Control Profile:
variable torque standard || optimized torque mode || constant torque standard
With Safety Function Safe Speed Monitor (Ssm):
FALSE
Volume Of Cooling Air:
103 m3/h
Variant:
standard version || with braking chopper
Maximum Transient Current:
28.2 A 60 s normal duty) || 24.8 A 60 s heavy duty)
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Assembly Style:
with heat sink
Relative Symmetric Network Frequency Tolerance:
0.05
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Environmental Characteristic:
chemical pollution resistance class 3C3 IEC 60721-3-3 || dust pollution resistance class 3S3 IEC 60721-3-3
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Discrete Input Type:
DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Discrete Output Number:
2
With Safety Function Safe Operating Stop (Sos):
FALSE
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 6...10 mm² AWG 10...AWG 8 || line side screw terminal 6 mm² AWG 10 || DC bus screw terminal 6 mm² AWG 10
Circularity Profile:
ENVEOLI2007010EN
With Safety Function Safe Programmable Logic:
FALSE
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Maximum Acceleration Under Vibrational Stress (During Operation):
10 m/s² at 13...200 Hz
Degree Of Protection:
UL type 12
Local Signalling:
local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Product Or Component Type:
variable speed drive
Base Load Current At Low Overload:
23.5 A
Isolation:
between power and control terminals
With Safety Function Safely Limited Position (Slp):
FALSE
Relay Output Number:
3
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
[Us] Rated Supply Voltage:
380...480 V - 15...10 %
Environmental Class (During Operation):
class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3