Schneider Electric

Schneider Electric ATV630D11M3 Variable Speed Drive Ip21 11Kw 200V/240V

(No reviews yet) Write a Review
SKU:
ATV630D11M3
UPC:
3606480701474
Condition:
New
Linearity Error:
AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Continuous Output Current:
46.8 A 4 kHz normal duty || 32.7 A 4 kHz heavy duty
Sustainable Offer Status:
Green Premium product
Variant:
standard version
Mercury Free:
Yes
[Us] Rated Supply Voltage:
200...240 V
Communication Port Protocol:
Ethernet || Modbus serial || Modbus TCP
Rohs Exemption Information:
Yes
Transmission Rate:
10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Accuracy:
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Input Compatibility:
DI1...DI6 discrete input level 1 PLC IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC IEC 61131-2
Refresh Time:
relay output R1, R2, R3)5 ms +/- 0.5 ms)
Emc Filter:
without EMC filter
Volume Of Cooling Air:
215 m3/h
Product Specific Application:
process and utilities
Local Signalling:
for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Quantity Per Set:
1
Analogue Output Number:
2
Apparent Power:
13.7 kVA 240 V normal duty) || 9.6 kVA 240 V heavy duty)
Discrete Input Type:
DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Frequency Resolution:
display unit 0.1 Hz || analog input 0.012/50 Hz
Product Or Component Type:
variable speed drive
Method Of Access:
slave Modbus TCP
Maximum Output Frequency:
500 kHz
Synchronous Motor Control Profile:
permanent magnet motor || synchronous reluctance motor
Analogue Output Type:
software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Electromagnetic Compatibility:
electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge im
Speed Drive Output Frequency:
0.1-500 Hz
Connector Type:
RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Maximum Transient Current:
51.5 A 60 s normal duty) || 49.1 A 60 s heavy duty)
Discrete Input Logic:
positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Product Certifications:
DNV-GL || UL || CSA || ATEX zone 2/22 || TÜV || ATEX INERIS
Pollution Degree:
2
Net Weight:
13.8 kg
Motor Slip Compensation:
can be suppressed || not available in permanent magnet motor law || automatic whatever the load || adjustable
Safety Function:
STO (safe torque off) SIL 3
Type Of Cooling:
forced convection
Relay Output Number:
3
Permissible Temporary Current Boost:
1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Physical Interface:
Ethernet || 2-wire RS 485
Relay Output Type:
configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Discrete Output Number:
0
Analogue Input Number:
3
Width:
211 mm
Phase:
3 phase
China Rohs Regulation:
X
Marking:
CE
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Operating Position:
vertical +/- 10 degree
Operating Altitude:
<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Sampling Duration:
2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Asynchronous Motor Control Profile:
optimized torque mode || variable torque standard || constant torque standard
Discrete Input Number:
8
Upgradeability:
Upgraded components available
Isolation:
between power and control terminals
Discrete And Process Manufacturing:
building - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compresso
Motor Power Kw:
11 kW normal duty) || 7.5 kW heavy duty)
Maximum Thdi:
<48 % from 80...100 % of load IEC 61000-3-12
Circularity Profile:
ENVEOLI1404008EN
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Storage:
-40-70 °C
Supply:
external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for d
Pollution Degree:
2 IEC 61800-5-1
Maximum Switching Current:
relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Discrete Output Type:
relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V
Overvoltage Category:
III
Ambient Air Temperature For Operation:
-15-50 °C without derating) || 50-60 °C with derating factor)
Option Card:
slot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A c
Data Format:
8 bits, configurable odd, even or no parity
Supply Frequency:
50...60 Hz - 5...5 %
Prospective Line Isc:
50 kA
Noise Level:
59.5 dB 86/188/EEC
Electrical Connection:
control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 16 mm² AWG 6 || line side screw terminal 10...16 mm² AWG 8...AWG 6
Depth:
232 mm
Power Range:
7-11 kW 200-240 V 3 phase
Number Of Addresses:
1-247 Modbus serial
Noise Level:
59.5 dB
Device Short Name:
ATV630
Enclosure Mounting:
wall mounted
Analogue Input Type:
AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Range Of Product:
Altivar Process ATV600
Environmental Disclosure:
ENVPEP1404008EN
Degree Of Protection:
UL type 1 UL 508C
Type Of Polarization:
no impedance
Minimum Switching Current:
relay output R1, R2, R3 5 mA 24 V DC
Switching Frequency:
2...12 kHz adjustable || 4...12 kHz with derating factor
Relative Humidity:
5-95 % without condensation IEC 60068-2-3
Transmission Frame:
RTU
Line Current:
39.3 A 200 V normal duty) || 32.9 A 240 V normal duty) || 27.2 A 200 V heavy duty) || 23.1 A 240 V heavy duty)
Mounting Mode:
wall mount
Regulation Loop:
adjustable PID regulator
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Power Dissipation In W:
natural convection 62 W 200 V 4 kHz || forced convection 452 W 200 V 4 kHz
Nominal Switching Frequency:
4 kHz
Acceleration And Deceleration Ramps:
linear adjustable separately from 0.01...9999 s
Ip Degree Of Protection:
IP21IEC 61800-5-1 || IP21IEC 60529
Discrete Input Logic:
16 preset speeds
Product Destination:
asynchronous motors || synchronous motors
Maximum Horse Power Rating:
15 hp normal duty || 10 hp heavy duty
Exchange Mode:
half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Braking To Standstill:
by DC injection
Vibration Resistance:
1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Standards:
UL 508C || IEC 61800-3 || IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Protection Type:
thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-c
Height:
546 mm
Output Voltage:
<= power supply voltage
[Us] Rated Supply Voltage:
200...240 V - 15...10 %
Insulation Resistance:
> 1 MOhm 500 V DC for 1 minute to earth
Brochure:
View
Catalog:
View
Datasheet:
View
$3,738.84

Description

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 200V to 240V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 11kW / 15hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 7.5kW / 10hp for applications requiring significant overload (up to 150%). It weighs 13.8kg and its dimensions are, 211mm wide, 546mm high, 232mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.
View AllClose