Evaluation unit for magnetically coded sensors with antivalent reed contacts
Functions:
For stop category 0,Start/restart interlock (RES),Static contactor monitoring (EDM)
Restart:
Automatic,Manual
SIL:
3, IEC 61508
SILCL:
3, IEC/EN 62061
Performance Level (PL):
e, EN ISO 13849-1
PFHD:
2,5E-08 per hour
Mission time:
20 years, EN ISO 13849-1
Category:
4, EN ISO 13849-1, (1 sensor connected)
STOP category:
0, IEC/EN 60204-1
Protective circuit:
Fuse on switching output, upstream
Continuous current per current path, max.:
3 A
Input current, max.:
150 mA
External contact fuse protection per current path:
4 A gG
Supply voltage UB:
24 V, AC/DC, -10 ... 10 %
Power consumption, max.:
4.6 W, For 24 V, plus output load
Number of safety-related switching outputs (OSSDs):
2 Piece(s)
Number of digital switching outputs:
1 Piece(s)
Type:
Safety-related switching output OSSD
Type:
Digital switching output
Switching element:
Relay, NC
Function:
EDM switching output
Number of outputs, safety-oriented, non-delayed, contact-based:
2 Piece(s)
Number of outputs, safety-oriented, delayed, contact-based:
0 Piece(s)
Number of outputs, signaling function, non-delayed, contact-based:
1 Piece(s)
Max. thermal continuous current Ith, release current paths:
3 A
Response time:
20 ms
Pickup delay, automatic start:
400 ms
Pickup delay, manual start:
600 ms
Regression delay:
20 ms
Time window between 2 channels of a sensor, max.:
500 ms
Number of connections:
1 Piece(s)
Function:
Connection to device,Voltage supply
Type of connection:
Terminal
Type of terminal:
Screw terminal
No. of pins:
16 -pin
Connection cross sections:
1 x 0.2 to 2.5 mm², wire,1 x 0.25 to 2.5 mm², wire with wire-end sleeve,2 x 0.2 to 1.0 mm², wire,2 x 0.2 to 1.5 mm², wire,2 x 0.5 to 1.5 mm², wire with twin wire-end sleeve,2 x 0.25 to 1.0 mm², wire with wire-end sleeve
Dimension (W x H x L):
22.5 mm x 99 mm x 113.6 mm
Housing material:
Plastic
Plastic housing:
PA
Net weight:
220 g
Housing color:
Gray
Type of fastening:
Snap-on mounting
Mechanical life time:
10,000,000 actuation cycles
Type of display:
LED
Number of LEDs:
3 Piece(s)
Ambient temperature, operation:
0 ... 55 °C
Ambient temperature, storage:
-25 ... 70 °C
Relative humidity (non-condensing):
4 ... 100 %
Degree of protection:
IP 20 (terminals),Installation in switch cabinet or housing with degree of protection of at least IP 54,IP 40 (housing)
Approvals:
TÜV Süd,c UL US
Test procedure for oscillation in accordance with standard: