- Series:
- MC336
- Functions:
- Integration in control circuits up to category4 in accordance with EN ISO 13849-1,Safety system in combination with an evaluation unit such as the MSI-MC310 safety relay or the MSI 400 safety controller.
- Mission time:
- 20 years, EN ISO 13849-1
- Category:
- Up to 4, depending on evaluation, 1 sensor connected, EN ISO 13849-1
- B10d:
- 20,000,000 number of cycles
- Protective circuit:
- Current limitation,Short circuit protected,Via e.g. MSI-MC310, MSI 400
- Contact allocation:
- 1NC + 1NO
- Contact type:
- Reed contacts (magnetically sensitive)
- Requirement on the voltage supply when used acc. to cULus (UL 508):
- Class 2 Circuits
- Max. switching voltage:
- 27 V AC/DC
- Switching current, max.:
- 500 mA
- Response time:
- 3 ms
- Number of connections:
- 1 Piece(s)
- Function:
- Contact connection
- Type of connection:
- Cable with wire-end sleeves
- Cable length:
- 2,000 mm
- Sheathing material:
- PVC
- Cable color:
- Gray
- Number of conductors:
- 4 -wire
- Design:
- Cubic
- Dimension (W x H x L):
- 26.2 mm x 13 mm x 36 mm
- Housing material:
- Plastic
- Plastic housing:
- Glass fiber reinforced (PPS), self-extinguishing
- Net weight:
- 149 g
- Housing color:
- Red
- Type of fastening:
- Through-hole mounting
- Installation position:
- Arbitrary, provided housing markings are aligned
- Switch type:
- Type 4 interlock device, contactless actuation, EN ISO 14119
- Approach actuation directions:
- 3-dimensional
- Mechanical life time:
- 10,000,000 actuation cycles
- External actuator:
- Magnetically coded
- Cut-out point (OFF), min.:
- 8 mm
- Assured cut-out distance (Sar), min.:
- 11 mm
- Assured cut-in distance (Sao), max.:
- 3 mm
- Switching tolerance (without ferromagnetic materials in immediate vicinity):
- -1 ... 1 mm
- Distance to other magnetic sensors, min.:
- 50 mm
- Approach speed, min.:
- 0.05 m/s
- Ambient temperature, operation:
- -20 ... 70 °C
- Degree of contamination:
- 3, EN 60947-1
- Degree of protection:
- IP 67
- Approvals:
- TÜV Süd (with suitable safety relay),c UL US
- Test procedure for EMC in accordance with standard:
- EN 60947-5-3,EN 61000-6-2,EN 61000-6-3
- Test procedure for oscillation in accordance with standard:
- EN 60947-5-3
- Test procedure for shock in accordance with standard:
- EN 60947-5-3
- Customs tariff number:
- 90328900
- ECLASS 5.1.4:
- 27272402
- ECLASS 8.0:
- 27272402
- ECLASS 9.0:
- 27272402
- ECLASS 10.0:
- 27272402
- ECLASS 11.0:
- 27272402
- ECLASS 12.0:
- 27274401
- ECLASS 13.0:
- 27274401
- ECLASS 14.0:
- 27274401
- ECLASS 15.0:
- 27274401
- ETIM 5.0:
- EC002544
- ETIM 6.0:
- EC002544
- ETIM 7.0:
- EC002544
- ETIM 8.0:
- EC002544
- ETIM 9.0:
- EC002544
- ETIM 10.0:
- EC002544
- Datasheet:
- View
- Brochure:
- View
- Declaration of Conformity:
- View