Baumer

Baumer UNAR 18N7912/S14G 10162127

(No reviews yet) Write a Review
SKU:
10162127
MPN:
10162127
Condition:
New
Special type:
Chemically robust
Scanning range Sd:
60 … 400 mm
Scanning range far limit Sde:
60 … 400 mm
Hysteresis typ.:
4 % Sde
Repeat accuracy:
0.5 mm
Temperature drift:
< 0,18 % Sde/K
Response time ton:
< 25 ms
Release time toff:
< 25 ms
Sonic frequency:
400 kHz
Adjustment:
Teach-in
Alignment aid:
Target indication flashing
Output indicator:
LED green
Approvals/certificates:
Ecolab
Voltage supply range +Vs:
12 … 30 VDC
Current consumption max. (no load):
35 mA
Output circuit:
NPN break function (NC)
Output current:
200 mA
Voltage drop Vd:
<2 VDC
Residual ripple:
< 10 % Vs
Short circuit protection:
Yes
Reverse polarity protection:
Yes
Design:
Cylindrical threaded
Housing material:
Stainless steel 1.4435 (V4A)
Coating active face:
Parylene
Material O-ring:
FFKM
Front of sensor durable against pressure:
6 bar, 20'000 cycle
Width / diameter:
18 mm
Height / length:
91.5 mm
Connection types:
Connector M12
Operating temperature:
0 … +60 °C
Protection class:
IP 67
Datasheet:
View
$859.00

Description

The Baumer UNAR 18N7912/S14G 10162127 is a chemically robust ultrasonic sensor designed for precise distance measurement within a scanning range of 60 to 400 mm. It features a repeat accuracy of 0.5 mm and a temperature drift of less than 0.18% Sde/K, ensuring reliable performance under varying conditions. The sensor has a quick response and release time of less than 25 ms, operates at a sonic frequency of 400 kHz, and includes a teach-in adjustment for easy setup. It is equipped with a target indication flashing for alignment aid, a green LED output indicator, and is Ecolab certified. The sensor supports a voltage supply range of 12 to 30 VDC, has a maximum current consumption of 35 mA, and includes safety features such as short circuit and reverse polarity protection. Its cylindrical stainless steel housing is durable, with a Parylene coating on the active face and an FFKM O-ring, capable of withstanding pressures up to 6 bar. The sensor's dimensions are 18 mm in width/diameter and 91.5 mm in height/length, and it connects via an M12 connector. It operates within a temperature range of 0 to +60 °C and meets IP 67 protection standards.
View AllClose