Baumer

Baumer OR18.ZI-PW1P.71O/B013 11157794

(No reviews yet) Write a Review
SKU:
11157794
MPN:
11157794
Condition:
New
Type:
Intensity difference
Sensing distance Tw:
< 300 mm
Alignment / soiled lens indicator:
LED green
Output indicator:
LED yellow
Sensing distance adjustment:
Potentiometer, 270°
Suppression of reciprocal influence:
YesLight source=Pulsed infrared diode
Wave length:
880 nm
Response time / release time:
< 1 ms
Voltage supply range +Vs:
12 … 30 VDC
Current consumption max. (no load):
40 mA
Current consumption typ.:
30 mA
Voltage drop Vd:
<2 VDC
Output function:
Light / dark operate
Output circuit:
PNP
Output current:
100 mA
Short circuit protection:
Yes
Reverse polarity protection:
Yes
Width / diameter:
18 mm
Height / length:
67.2 mm
Design:
Cylindrical threaded
Housing material:
Plastic (ABS TERLURAN)
Front (optics):
PMMA
Connection types:
Connector M12 4 pin
Protection class:
IP 67
Operating temperature:
-25 … +55 °C
Datasheet:
View
$79.00

Description

The Baumer OR18.ZI-PW1P.71O/B013 11157794 is an intensity difference sensor with a sensing distance of less than 300 mm. It features a green LED for alignment or soiled lens indication and a yellow LED output indicator. The sensor's distance can be adjusted via a 270° potentiometer and includes suppression of reciprocal influence. It utilizes a pulsed infrared diode light source with a wavelength of 880 nm and boasts a quick response and release time of less than 1 ms. Operating on a voltage supply range of 12 to 30 VDC, it has a maximum no-load current consumption of 40 mA and a typical consumption of 30 mA. The output function can operate in light or dark conditions, and it includes a PNP output circuit with a maximum output current of 100 mA. Safety features include short circuit and reverse polarity protection. The sensor has a cylindrical threaded design, measuring 18 mm in width and 67.2 mm in length, with a housing made of ABS plastic and a PMMA front optics. It connects via an M12 4-pin connector and is rated IP67, making it suitable for harsh environments. Operating temperatures range from -25 to +55 °C.
View AllClose